DESCRIPTION
The 1335A High Resolution Storage Display is designed to meet the high resolution and imaging requirements of OEM scientific measurement and diagnostic systems.
▪ Adds the versatility of storage capability
▪ Offers an exceptionally uniform display
▪ Unit increases persistence to match the refresh rate for monitoring slowly changing phenomena
▪ Retains sharp details with a resolution of 50 lines/inch (in storage mode)
▪ Select operating modes manually with front-panel controls, remotely with program inputs, or with a combination of both
OPTIONS === X and Y Amplifiers ===
<--- Deflection Factor --->
• Option 100 = 500 mV/div, 5 V p-p full scale deflection
• Option 101 = 1 V/div, 10 V p-p for full scale deflection
<--- Polarity --->
• Option 105 = Negative X and Y inputs move beam up and right (BNC connectors)
• Option 106 = Full differential input, shield grounded (BNC connectors)
<--- Input Impedance --->
• Option 110 = 50-ohms
=== Z-Axis Input (Video Amp)===
<--- Blanking Range --->
• Option 200 = 0 to 5 V
• Option 201 = 0 to 10 V
<--- Polarity --->
• Option 205 = Negative input unblanks trace, BNC connector with shield grounded
• Option 206 = Full differential input, BNC connector with shield grounded
<--- Input Impedance --->
• Option 210 = 50-ohms
<--- Gain Characteristics --->
• Option 215 = Light output varies linearly (±20%) with a change in Z-axis input voltage (gamma correction)
<--- Digital Input --->
• Option 216 = TTL blanking level. High state (+2.5 V to + 5 V) blanks any analot Z-axis input signal. Low state (0.0 V to + 0.8 B) returns blanking to analog Z-axis input
=== Cathode-Ray Tube ===
<--- Graticule/Phosphor Type --->
• Option 631 = P31 aluminized phosphor without internal graticule
<--- Contrast Filters --->
• Option 561 = Clear, impact resistant, replaces filter supplied with standard and some optional phosphors
• Option 562 = Clear, RFI coated surface with metalized front panel (not UL or CSA recognized or listed)
• Option 563 = Gray, impact resistant, replaces filter supplied with standard and some optional phosphors
=== Documentation ===
• Option 500 = Delete Service Manual
=== Interface Suppression ===
• Option 551 = Includes special power transformer with special shielding, and improved shielding of cathode-ray tube.
=== AC Line Cords ===
• Option 300 = 2.3 m (7.5 ft) removable, 240 V max, 3 conductor 90º IEC to Great Britain Singapore
• Option 301 = 2.3 m (7.5 ft) removable, 240 V max, 3 conductor IEC ACCESSORIES • Blue impact resistant contrast filter
• Line Cord
• Operating Manual
• Remote Program Connector |