DESCRIPTION
The 1332A Small Screen Display is designed primarily as a readout or monitoring instrument capable of displaying wide-band, X, Y, & Z information for OEM systems application. The CRT has the resolution & picture quality required for medical diagnostic systems, plus an extremely bright display needed for differentiating between many gray shades. Electrical performance has been extended to 5MHz to meet the display needs of today's OEM systems & digital processors. Spot resolution is 0.305 mm (0.012 in.) in diameter at high intensity levels & remains extremely well focused over the entire range of intensity levels. Spot resolution, within the quality area, varies by less than 10% making the display especially useful in applications where sharp focus is required throughout the quality area.
• X-Y Amplifiers Rise Time <70 nsec (10% to 90% points) for full screen deflection
• Bandwidth: DC to 5MHz (3 dB down) for 3 inch (7.62 cm) deflection
• Phase Shift <1° (DC to 1MHz)
• Settling Time <300 ns for any Large or Small Movement
OPTIONS • === X and Y Amplifiers ===
• <--- Deflection Factor --->
• Option 100 = 500 mV/div, 5 V p-p full scale deflection
• Option 101 = 1 V/div, 10 V p-p for full scale deflection
• <--- Polarity --->
• Option 105 = Negative X and Y inputs move beam up and right (BNC connectors)
• Option 106 = Full differential input, shield grounded (BNC connectors)
• <--- Input Impedance --->
• Option 110 = 50-ohms
• <--- Rise Time --->
• Option 120 = 25 ns X and Y amplifier rise time
• === Z-Axis Input (Video Amplifier) ===
• <--- Blanking Range --->
• Option 200 = 0 to 5 V
• Option 201 = 0 to 10 V
• <--- Polarity --->
• Option 205 = Negative input unblanks trace, BNC connector with shield grounded
• Option 206 = Full differential input, BNC connector with shield grounded
• <--- Input Impedance --->
• Option 210 = 50-ohms
• <--- Gain Characteristics --->
• Option 215 = Light output varies linearly (±20%) with a change in Z-axis input voltage (gamma correction)
• <--- Digital Input --->
• Option 216 = TTL blanking level. High state (+2.5 V to + 5 V) blanks any analot Z-axis input signal. Low state (0.0 V to + 0.8 B) returns blanking to analog Z-axis input
• === Cathode-Ray Tube ===
• <--- Graticule / Phosphor Type --->
• Option 004 = P4 aluminized phosphor with 8 x 10 div internal graticule
• Option 007 = P7 aluminized phosphor with 8 x 10 division internal graticule and amber contrast filter (not UL or CSA recognized or listed)
• Option 011 = P11 aluminized phosphor with 8 x 10 division internal graticule
• Option 039 = P39 aluminized phosphor with 8 x 10 division internal graticule
• Option 604 = P4 aluminized phosphor without internal graticule
• Option 607 = P7 aluminized phosphor with amber filter, without internal graticule (not UL or CSA recognized or listed)
• Option 611 = P11 aluminized phosphor without internal graticule
• Option 631 = P31 aluminized phosphor without internal graticule
• Option 639 = P39 aluminized phosphor without internal ACCESSORIES • Blue impact resistant contrast filter
• Line Cord
• Operating Manual |
Refurbished
|
 |
Price: Call for Quote
Status: Call for Quote
Download
Specs
| Call Now |
 |
877-667-6044
/ 214-348-8800 |
Television / Video Test Equip.
See
Similar Products
Why Tucker
Rent it
Lease it
Our Warranty
Certified Quality
Return to Results
Page |